Print Document

Page 1/12

Please consider the environment before printing this document.

English: Select your language from the drop-down box above.
German: Wählen Sie Ihre Sprache aus dem Dropdown-Feld oben aus.
Spanish: Seleccione su idioma en el cuadro desplegable de arriba.
French: Sélectionnez votre langue dans la liste déroulante ci-dessus.
Italian: Seleziona la tua lingua dalla casella a discesa in alto.

Change language translation at any time.

If any of the information printed in this document appears unclear or is incorrect please report it to us by emailing TropiCoolCare@Gmail.com

 

Electric Bed Mattress Cooling

Thank you for choosing TropiCool bed acclimatising system a remarkably versatile product which offers a choice of Air-conditioned bed cooling in summer and bed warming in winter, or if you have a dual control system your partner can have bed warming or cooling on their side while you choose your preferred option on your side.

This acclimatising system has been designed and manufactured to high standards of engineering and with proper use and care, as described in this leaflet, the appliance will give you years of useful service.

 






Page 2/12

General Care and Safety

Please read the following carefully.






Page 3/12

General Care and Safety Guide Continued.....
  • Clean the appliance with a wet clean cloth or anti-electrostatic cloth.
  • Do not clean the outside of the appliance with chemical cleaners.
  • Caution increased incidents of static electrical discharge.
Cleaning
Electric Bed Cooling Clean 2
Electric Bed Cooling Stat

Disposal of your old appliance

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or municipal office for recycling advice.

Recycle

 






Page 4/12

Parts List

 

Part 

Quantity

Solo - Single appliance

Companion - Twin appliances

TropiCool Control Unit

TropiCool HC Control Unit

1

2

TropiCool Parts 3

˜Remote Control

1

2

TropiCool Part 3

TropiCool Mattress Pad

1

2

TropiCool part 4

1.5 m Tube

1

2

TropiCool 5

Water Drainage Key

1

2

 

Control Unit

Item  Description Item  Description
1 - Water Tank 7 - Tube Release Button
2 - Water Input 8 - Foot Pad
3 - Fan Grill 9 - Air Vent
4 - Carry Handle    
5 - Power Cable    
6 - Control Panel    
View from Above     View from Underside    

 






Page 5/12

Product setup 1

1. Fitting the Mattress Topper
Place the TropiCool mattress topper on top of your mattress with the connection (3) at the foot or head of the bed depending on your preferred layout and the location of the unit(s). Secure the mattress topper with the elasticated straps at each corner §Note Below and place a sheet or mattress protector over the topper (1).
Attach the female socket MT2(1) into the mail connection (3) at the opposite end using the male connection (2) attach into the female socket MT3(1)

TropiCool topper Img Reference  Description
MT1(1) TropiCool Topper
MT1(2) Mattress
MT1(3) Mattress Connection Point
MT1(4) Alternative Position for a Connection
   
MT2(1) Female Socket
MT2(2) Male Connector Plug
MT2(3) 1.5M Long Tube
 
TropiCool Unit MT3

TropiCool Tube

2. Positioning

To fit the cooling and heating blanket place on your mattress with the connectors either at the bottom or the top of the bed depending on your layout i.e. if the control unit is to sit at the head or the foot of the bed.

Face the blanket either way up this does not affect the efficiency. Secure the blanket by attaching elasticated straps in each corner over your existing mattress once fitted cover with a mattress topper or a single sheet or both. (Important do not use in conjunction with any electric blanket)

If you have purchased a double blanket with the solo unit you can attach the tube to either side of the blanket depending on user preference. Only one side of the bed will be cooled or heated, at the end of each tube is a connector which has a valve so it is safe to remove the tube with fluid in it however we would advise against leaving fluid in the blanket for long periods and would instead suggest you use the drain key to remove water if not in use for extended periods. If required additional control units can be purchased separately which will turn a double mattress with the solo unit into a Companion model giving users on either side of the mattress personalised heating or cooling functionality; please email us for details.

§ If fitting a solo TropiCool mattress onto a double/king-size bed.
Leave the elasticated straps loose positioned underneath the mattress the silicon matrix enclosed within the mattress will keep the TropiCool mattress in place on the bed if however, if you experience a problem please contact us and we will send you a simple kit to rectify this.

TropiCool connecting 1 TropiCool connecting 2
   
TropiCool Connecting 3 TropiCool connection 4

3. Connecting Pad Tube and Control Unit.
IMPORTANT Push all connectors in firmly until they click and lock into place. The flow will automatically stop if the tube is disconnected
a)
Connect the male plug on the tube CN1(1) also MT2(2) with the female socket (2) on the control unit.  See CN2 correctly fitted.
b) Connect the female socket on the tube CN3(1) also MT2(1) with the male plug (2) on the mattress pad. See CN4 correctly fitted.

Tube

 






Page 6/12

Setting up Continued...

C. Switch On - Add Water - Prime the Mattress.

Remove the cap on the water tank (1) and fill with water until the tank is full the level is visible through the clear window (2). On the control panel or the remote press, the power button (4) to ON  the water starts to circulate through the silicon tubes the water level in the unit will drop top up to the maximum level, add additional water until the tank remains full.  Finally, replace the cap.

Tips for Your TropiCool

  1. Carefully pour the water avoiding spilling into the unit (1) use a funnel if necessary.
  2. Check the water levels regularly. The clear window (2) on the side helps you see where the level is. Under normal use, the unit will not need refilling for many days but this can change depending on air temperature and whether heating or cooling mode is selected.
  3. Use good quality tap water do not use oils, chemicals or cleaners as this can damage the mechanism. If your water contains high levels of dissolved minerals such as calcium and magnesium we suggest using deionised or distilled water.

 

TropiCool filling with water

 

D. Control Panel      
1 - Low Water Warning Light
Control panel 2 - Temperature  Format Degrees ° C or ° f
3 - Sleep Mode ♣(NB)
4 - Power ON /OFF
5 - Set Timer
6 - Enter / Confirm
7 - Temperature Down
8 - Temperature Up
9 - Dynamic Vision
10 - ON/OFF Indicator Light
11 - Dynamic Vision
12 - The receiver for the optional remote - Leave Uncovered
   

Note: Dynamic vision light will flash when manual control is in use

♠(NB) SLEEP MODE (3) this will switch on the ambient temperature mode whereby after ONE HOUR TropiCool will automatically set your cooling or heating temperature to a factory adjusted AMBIENT temperature of between 31° C and 36° C. If cooling was previously selected then the temperature will steadily increase until it reaches 31° C if heating was previously selected the temperature will gradually fall to 36° C These are considered comfortable nighttime sleeping temperatures and will not overwork the HC unit over long periods in ambient mode the fan speed is greatly reduced and only speeds up if the thermostat needs to readjust the HC units temperature. If you wish to use this function press SLEEP MODE (3) then ENTER (6) to confirm. To cancel this mode at any time you can increase or decrease the temperature by pressing the up or down arrow.






Page 7/12

Remote Control
Buttons Electric bed cooling Remote control Batteries Remote control batteries
1. ON or OFF ƒ 9. 2 AAA Batteries (Not Supplied)
2. Temperature DOWN
3. Temperature UP 10. Battery Compartment Clip-on Cover
4. Current Setting
5. Enter  
6. Sleep Mode  
7. Temperature scale °C or F  
8. Timer  

ƒ Remote Control Due to restrictions placed upon us by our delivery agent we are unable to enclose batteries within our boxes. 2 batteries are required for the remote control please accept our apologies for not being able to provide them however AAA batteries are easily obtainable from most general stores.

Control Unit Display 

On / Off  
Timer Enter
Warming Enter
Cooling Enter
Shift  
Sleep  

Index

Control Unit Marks and Light
Flashing ¦¦¦¦
Stop State Low Water Warning Power ON/OFF Timing Warming Cooling Manual Control Confirm °F/°C Sleeping Mode

Cleaning Tips for your TropiCool Mattress Topper 






Page 8/12

Control Unit Technical Information Continued

 

Input Voltage

AC220V

Rated Frequency

50-60Hz

Start Cooling Wattage

180W +/- 10%

Start Warming Wattage

200W+/- 10%

Stay Cool constant Wattage

80 Watt +/- 10%

Stay Warm constant Wattage

80W+/- 10%

Noise

Less Than 45dB

Maximum Timer Setting

12 Hours

Temperature Range °C*

18° C to 46° C

Temperature Range °F *

64° F to 115°F

* Temperature Range. The lowest factory pre-set cooling temperature is 18°C/64°F. You can set the unit temperature level lower than this, however, depending on external factors such as room temperature the unit will not go below the factory pre-set.

Item Description
1 - Carry Handle
2 - Air Inlet
3 - Heat Vent
4 - Control panel
5 - Impact resistant plastic housing
6 - Tube Connection Point (Flow Will Automatically Stop if Tube is Disconnected)
7 - Water Inlet (Fill With Pure Water)





Page 9/12

Maintenance

A. Cleaning: Regularly clean dirt and dust off the fan protector on the front of the control unit. Clean the dirt off inside the window of the Control Unit. If this builds up it affects the efficiency of the unit. The user can take off the fan lid off to clean or wash, dry and then refit to the control unit.

B. Emptying water from the control unit and mattress:

If the system has not been used for an extended period of time we recommend flushing the water and refilling with fresh.

To do this turn on the control unit and let the water circulate in the mattress for 2 to 3 minutes before disconnecting pipe, topper and control unit, then empty the water using the plastic key to release the valves on the tube and the unit making sure you have to drain the water into. Once empty, refill the tank with new water connect tubes and mattress topper to circulate the freshwater topping up as the reservoir falls.

Disconnecting Tubes

Press the button (2) under the unit to release the tube (1)
Electric bed cooling






Page 10/12

Trouble Shooting 

 

Symptom Possible Reason Trouble Shooting
Cannot Start

No Power

Turn ON Power 

Power not Connected

Check all connections

Blown Fuse

Check the fuse/replace

Power not on, but LED Light is ON

Low water level. ADD water

Remote Control not responding

Replace Batteries
All lights ON but not working

Turn OFF the power. Clean and Dry the Control Unit.  Restart

Possible issues with the Control Unit

Noise coming from the Control Unit due to lack of water

ADD Water

Air Inlet is covered and blocked by dirt and dust

Take the Metal Grill off and clean

Unable to change the temperature either UP or DOWN

Something is blocking the Control Unit Heat Vent

Check it, then Clean if dusty of blocked

Not enough water in the Tank

ADD Water

If the problems below occur, STOP using the unit and turn OFF the Power
The Problem

The Fuse blows frequently

Service is required

Water is accidentally split inside the Control Unit

Ensure it has time to dry completely before reusing

Unusual smell or noise

Clean the Vent and check for blockages






Page 11/12

Guarantee

Our promise
If your purchase was delivered faulty, damaged or with any components missing then please report this to us and we will replace the unit or send the missing parts free of charge.

Contact us by email to request a warranty repair. Please provide your purchase details including order number, date, retailers name, country of purchase and a description of the problem.

Contact Email: TropiCoolCare@Gmail.com

 






Page 12/12

Product Guarantee

This product is guaranteed against manufacturing defects for a period of

2 Years
YEARS

This product is guaranteed for 2 years from the date of original purchase.  Any defect that arises due to faulty materials or workmanship will either be replaced refunded or repaired free of charge where possible during this period.

The guarantee subject to the following provisions:

TropiCool Logo






Press 'Complete' when done editing.